Quick Shipment for Full Safety Sensor Replacement

Home / All / Banner Replacement / BANNER Measuring Light Curtains Replacement /

For Banner Mini-Array Series Two-Piece Measuring Light Curtain Replacement 19.1 mm Beam spacing | 13.5 or 16.5 Operating Range | 150 mm to 1830 mm Protective Height

For Banner Mini-Array Series Two-Piece Measuring Light Curtain Replacement 19.1 mm Beam spacing | 13.5 or 16.5 Operating Range | 150 mm to 1830 mm Protective Height

For Banner Mini-Array Series Two-Piece Measuring Light Curtain Replacement 19.1 mm Beam spacing | 13.5 or 16.5 Operating Range | 150 mm to 1830 mm Protective Height
For Banner Mini-Array Series Two-Piece Measuring Light Curtain Replacement 19.1 mm Beam spacing | 13.5 or 16.5 Operating Range | 150 mm to 1830 mm Protective HeightFor Banner Mini-Array Series Two-Piece Measuring Light Curtain Replacement 19.1 mm Beam spacing | 13.5 or 16.5 Operating Range | 150 mm to 1830 mm Protective HeightFor Banner Mini-Array Series Two-Piece Measuring Light Curtain Replacement 19.1 mm Beam spacing | 13.5 or 16.5 Operating Range | 150 mm to 1830 mm Protective HeightFor Banner Mini-Array Series Two-Piece Measuring Light Curtain Replacement 19.1 mm Beam spacing | 13.5 or 16.5 Operating Range | 150 mm to 1830 mm Protective HeightFor Banner Mini-Array Series Two-Piece Measuring Light Curtain Replacement 19.1 mm Beam spacing | 13.5 or 16.5 Operating Range | 150 mm to 1830 mm Protective Height
CategoriesBANNER Measuring Light Curtains Replacement
BrandDADISICK
ModelMini-Array Series | MAE616Q, MAE1216Q, MAE1816Q, MAE2416Q, MAE3016Q, MAE3616Q, MAE4216Q, MAE4816Q, MAE5416Q, MAE6016Q, MAE6616Q, MAE7216Q, MAR616NX485Q, MAR1216NX485Q, MAR1816NX485Q, MAR2416NX485Q, MAR3016NX485Q, MAR3616NX485Q, MAR4216NX485Q, MAR4816NX485Q, MAR5416NX485Q, MAR6016NX485Q, MAR6616NX485Q, MAR7216NX485Q
Series:Mini-Array Series
Beam spacing:19.1 mm
Number of beams:8/16/24/32/40/48/56/64/72/80/88/96
Operating range:0.9 m - 13. 5 m / 0.9 m - 16.5 m
Protective height:150 mm - 1830 mm
Output type:NPN & PNP / RS485 output
Connection type:M12
IP Degree of protectionIP65
Update TimeNov 21,2024
Detail Information
For Banner Mini-Array Series Two-Piece Measuring Light Curtain Replacement Parameter
Brand
From network
DADISICK
Emitter
Receiver
Models
MAE616Q
MAR616NX485Q
QLV08-20-140
MAE1216Q
MAR1216NX485Q
QLV16-20-300
MAE1816Q
MAR1816NX485Q
QLV24-20-460
MAE2416Q
MAR2416NX485Q
QLV32-20-620
MAE3016Q
MAR3016NX485Q
QLV40-20-780
MAE3616Q
MAR3616NX485Q
QLV48-20-940
MAE4216Q
MAR4216NX485Q
QLV56-20-1100
MAE4816Q
MAR4816NX485Q
QLV64-20-1260
MAE5416Q
MAR5416NX485Q
QLV72-20-1420
MAE6016Q
MAR6016NX485Q
QLV80-20-1580
MAE6616Q
MAR6616NX485Q
QLV88-20-1740
MAE7216Q
MAR7216NX485Q
QLV96-20-1900
Beam spacing
19.1 mm
20 mm
Number of beams
8, 16, 24, 32, 40, 48, 56, 64, 72, 80, 88, 96
8, 16, 24, 32, 40, 48, 56, 64, 72, 80, 88, 96
Protective height
143 mm, 295 mm, 448 mm, 600 mm, 
752 mm, 905 mm, 1057 mm, 1210 mm, 
1362 mm, 1514 mm, 1667 mm, 1819 mm
140 mm, 300 mm, 460 mm, 620 mm, 
780 mm, 940 mm, 1100 mm, 1260 mm, 
1420 mm, 1580 mm, 1740 mm, 1900 mm
Operating range
0.9 m - 13. 5 m / 0.9 m - 16.5 m
0.3 m - 15 m
Output method
NPN & PNP output
RS485 output
NPN & PNP output
RS485 output
IP Degree of protection
IP65
IP65
Connector
M12
M16
Housing cross-section
36.1 mm × 38.1 mm
51 mm × 35 mm
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand Banner's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
DADISICK Measuring Light Curtains
QLV series measuring light curtains
Model:
QLV08-20-140, QLV16-20-300, QLV24-20-460, 
QLV32-20-620, QLV40-20-780, QLV48-20-940, 
QLV56-20-1100, QLV64-20-1260, QLV72-20-1420, 
QLV80-20-1580, QLV88-20-1740, QLV96-20-1900

FAQ
What factors should be considered when selecting a Measuring Light Curtain?
A: Key factors include resolution, detection range, response time, number and spacing of beams, environmental suitability (e.g., resistance to dust and moisture), installation ease, power requirements, and interface compatibility.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Measuring Light Curtain Wiring Diagrams/Dimensional Drawings
Measuring Light Curtain Cable description
DADISICK Measuring Light Curtain Cable Description
Measuring Light Curtain
 Dimension
DADISICK Measuring Light Curtain Dimension
Protective Cover Dimension
DADISICK Measuring Light Curtain Protective Cover Dimension
Measuring Light Curtain QLV Series Data Sheet
Review
  • Loading...
Please send your message to us
*Email
Tel
*Title
*Content
Upload
  • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.
Industrial Automation Security Solutions