Quick Shipment for Full Safety Sensor Replacement

Home / All / Ultrasonic Sensor Replacement / UST-M30PS Series Standard Body Diffuse M30 Ultrasonic Sensors Replacement /

UST-M30PS Series Standard Body Diffuse M30 PBTP Ultrasonic Sensors Replacement | Sensing Range 200 mm to 2500 mm and 350 mm to 3500 mm

UST-M30PS Series Standard Body Diffuse M30 PBTP Ultrasonic Sensors Replacement | Sensing Range 200 mm to 2500 mm and 350 mm to 3500 mm

UST-M30PS Series Standard Body Diffuse M30 PBTP Ultrasonic Sensors Replacement | Sensing Range 200 mm to 2500 mm and 350 mm to 3500 mm
UST-M30PS Series Standard Body Diffuse M30 PBTP Ultrasonic Sensors Replacement | Sensing Range 200 mm to 2500 mm and 350 mm to 3500 mmUST-M30PS Series Standard Body Diffuse M30 PBTP Ultrasonic Sensors Replacement | Sensing Range 200 mm to 2500 mm and 350 mm to 3500 mmUST-M30PS Series Standard Body Diffuse M30 PBTP Ultrasonic Sensors Replacement | Sensing Range 200 mm to 2500 mm and 350 mm to 3500 mmUST-M30PS Series Standard Body Diffuse M30 PBTP Ultrasonic Sensors Replacement | Sensing Range 200 mm to 2500 mm and 350 mm to 3500 mmUST-M30PS Series Standard Body Diffuse M30 PBTP Ultrasonic Sensors Replacement | Sensing Range 200 mm to 2500 mm and 350 mm to 3500 mm
CategoriesUST-M30PS Series Standard Body Diffuse M30 Ultrasonic Sensors Replacement
BrandDADISICK
ModelUST-M30PS Series | UST-M30PS-TLS-101, UST-M30PS-TLS-603, UST-M30PS-TLS-301, UST-M30PS-TLS-403, UST-M30PS-TLS-711, UST-M30PS-TLS-729, UST-M30PS-TLS-72A, UST-M30PS-TLS-813, UST-M30PS-TLS-839, UST-M30PS-TLS-83A, UST-M30PS-TMS-101, UST-M30PS-TMS-603, UST-M30PS-TMS-301, UST-M30PS-TMS-403, UST-M30PS-TMS-711, UST-M30PS-TMS-729, UST-M30PS-TMS-72A, UST-M30PS-TMS-813, UST-M30PS-TMS-839, UST-M30PS-TMS-83A
Series:UST-M30PS Series
Size:M30
Sensing Distance:200...2500 mm / 350...3500 mm
Output Method:PNP / NPN / Analog output
Connection Type:M12 4-pin / M12 5-pin
Security level:IP67
Material:PBTP
Update TimeSep 19,2024
Detail Information

UST-M30PS Series Standard Body Diffuse M30 PBTP Ultrasonic Sensors Replacement Parameter

Brand
From network
DADISICK
Models
UST-M30PS-TLS-101
CSB30-4000-J60-E7-V15
UST-M30PS-TLS-603
CSB30-4000-J60-E6-V15
UST-M30PS-TLS-301
CSB30-4000-J60-E2-V15
UST-M30PS-TLS-403
CSB30-4000-J60-E3-V15
UST-M30PS-TLS-711
CSB30-4000-J60-E7-V15
UST-M30PS-TLS-729
CSB30-4000-J60-IE4-V15
UST-M30PS-TLS-72A
CSB30-4000-J60-UE4-V15
UST-M30PS-TLS-813
CSB30-4000-J60-E8-V15
UST-M30PS-TLS-839
CSB30-4000-J60-IE5-V15
UST-M30PS-TLS-83A
CSB30-4000-J60-UE5-V15
UST-M30PS-TMS-101
CSB30-4000-J60-E7-V15
UST-M30PS-TMS-603
CSB30-4000-J60-E6-V15
UST-M30PS-TMS-301
CSB30-4000-J60-E2-V15
UST-M30PS-TMS-403
CSB30-4000-J60-E3-V15
UST-M30PS-TMS-711
CSB30-4000-J60-E7-V15
UST-M30PS-TMS-729
CSB30-4000-J60-IE4-V15
UST-M30PS-TMS-72A
CSB30-4000-J60-UE4-V15
UST-M30PS-TMS-813
CSB30-4000-J60-E8-V15
UST-M30PS-TMS-839
CSB30-4000-J60-IE5-V15
UST-M30PS-TMS-83A
CSB30-4000-J60-UE5-V15
Thread Size
M30
M30
Sensing Distance
200...2500 mm / 350...3500 mm
200 mm - 4000 mm
Output Method
NPN or PNP: NO/NC + NO/NC
NPN or PNP: NO/NC
NPN or PNP: NO/NC SYNC/MUX
NPN or PNP: Analog current 4-20 mA
NPN or PNP: Analog voltage 0-10 V
2*NPN or 2*PNP: NO/NC
NPN or PNP: NO/NC
NPN or PNP: Analog current 4-20 mA
NPN or PNP: Analog voltage 0-10 V
Analog + push pull output, support IO-Link
Connector
M12 4-pin / M12 5-pin
M12
Security level
IP67
IP67
Material
PBTP
Nickel plated copper
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product model display instructions
The product models displayed on this page are only used to describe and compare the characteristics, specifications, and performance of different products. These models do not represent recommendations or associations for any specific brand or company. When users choose products, please understand and compare the detailed information of each brand's products on your own.
Product recommendations
DADISICK Ultrasonic sensors CSB30 series
Model: 
CSB30-4000-J60-E2-V15, CSB30-4000-J60-E3-V15, 
CSB30-4000-J60-E6-V15, CSB30-4000-J60-E7-V15, 
CSB30-4000-J60-E8-V15, CSB30-4000-J60-IE4-V15, 
CSB30-4000-J60-IE5-V15, CSB30-4000-J60-UE4-V15, 
CSB30-4000-J60-UE5-V15

FAQ
 How can ultrasonic sensors be protected from interference?
A: Ultrasonic sensors employ a specific frequency of ultrasound and internal algorithms to filter out noise and interference, thereby enhancing the reliability and accuracy of the measurement.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Dimensions
Dimensions  (Unit: Mm)
Ultrasonic sensors CSB30 series Dimensions
Reference Curve
DADISICK Ultrasonic sensors CSB30 series Reference Curve
Ultrasonic sensors CSB30 series data sheet
Ultrasonic sensors CSB30 series operation instructions
Related Products
    Review
    • Loading...
    Please send your message to us
    *Email
    Tel
    *Title
    *Content
    Upload
    • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.
    Industrial Automation Security Solutions