Quick Shipment for Full Safety Sensor Replacement

Home / All / ReeR Replacement / ReeR Safety Light Curtains Replacement /

For ReeR EOS2 Series 50 mm Resolution 12 m Sensing Distance 160 mm to 2260 mm Protective Height A Safety Light Curtain Replacement

For ReeR EOS2 Series 50 mm Resolution 12 m Sensing Distance 160 mm to 2260 mm Protective Height A Safety Light Curtain Replacement

For ReeR EOS2 Series 50 mm Resolution 12 m Sensing Distance 160 mm to 2260 mm Protective Height A Safety Light Curtain Replacement
For ReeR EOS2 Series 50 mm Resolution 12 m Sensing Distance 160 mm to 2260 mm Protective Height A Safety Light Curtain ReplacementFor ReeR EOS2 Series 50 mm Resolution 12 m Sensing Distance 160 mm to 2260 mm Protective Height A Safety Light Curtain ReplacementFor ReeR EOS2 Series 50 mm Resolution 12 m Sensing Distance 160 mm to 2260 mm Protective Height A Safety Light Curtain ReplacementFor ReeR EOS2 Series 50 mm Resolution 12 m Sensing Distance 160 mm to 2260 mm Protective Height A Safety Light Curtain ReplacementFor ReeR EOS2 Series 50 mm Resolution 12 m Sensing Distance 160 mm to 2260 mm Protective Height A Safety Light Curtain Replacement
CategoriesReeR Safety Light Curtains Replacement
BrandDADISICK
ModelEOS2 Series | EOS2 155 A, EOS2 305 A, EOS2 455 A, EOS2 605 A, EOS2 755 A, EOS2 905 A, EOS2 1055 A, EOS2 1205 A, EOS2 1355 A, EOS2 1505 A, EOS2 1655 A, EOS2 1805 A, EOS2 1955 A, EOS2 2105 A, EOS2 2255 A
Series:EOS2 Series
Resolution:50 mm
Scanning range:12 m
Protective field height:160 - 2260 mm
2 Safety outputs (OSSD):2 PNP
Response time:3.5 - 16 ms
Connection type:M12
security level:PLc2
Update TimeNov 23,2024
Detail Information
For ReeR EOS2 Series 50 mm Resolution 12 m Sensing Distance 160 mm to 2260 mm Protective Height A Safety Light Curtain Replacement Parameter
Brand
From network
DADISICK
Models
EOS2 155 A
QT06-40-200 2BD
EOS2 305 A
QT08-40-280 2BD
EOS2 455 A
QT12-40-440 2BD
EOS2 605 A
QT16-40-600 2BD
EOS2 755 A
QT20-40-760 2BD
EOS2 905 A
QT24-40-920 2BD
EOS2 1055 A
QT28-40-1080 2BD
EOS2 1205 A
QT32-40-1240 2BD
EOS2 1355 A
QT36-40-1400 2BD
EOS2 1505 A
QT38-40-1480 2BD
EOS2 1655 A
QT42-40-1640 2BD
EOS2 1805 A
QT46-40-1800 2BD
EOS2 1955 A
QT50-40-1960 2BD
EOS2 2105 A
QT54-40-2120 2BD
EOS2 2255 A
QT58-40-2280 2BD
Beam spacing
50 mm
40 mm
Protected altitude
160 mm, 310 mm, 460 mm, 610 mm, 760 mm, 910 mm,1060 mm, 1210 mm, 1360 mm, 1510 mm, 1660 mm, 1810 mm, 1960 mm, 2110 mm, 2260 mm
200 mm, 280 mm,440 mm, 600 mm, 760 mm, 920 mm,  1080 mm, 1240 mm, 1400 mm, 1480 mm, 1640 mm, 1800 mm, 1960 mm, 2120 mm, 2280 mm 
Scanning range
12 m
0.3 - 15 m
Response time
3.5 - 19 ms
≤15 ms
Output method
2 PNP
2 PNP
Reliability and durability
IP65, IP67
IP65
Connector
M12
M16
Housing cross-section
28 mm x 30 mm
51 mm x 35 mm
Safety Certificate
CE, TÜV, UL, TS, RoHS, UKCA, PLc2
TÜV, UL, CE, RoHS, GB
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand ReeR's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
DADISICK QT Series Machine Light Curtains
Model:
QT06-40-200 2BD, QT08-40-280 2BD, QT12-40-440 2BD
QT16-40-600 2BD, QT20-40-760 2BD, QT24-40-920 2BD
QT28-40-1080 2BD, QT32-40-1240 2BD, QT36-40-1400 2BD
QT38-40-1480 2BD, QT42-40-1640 2BD, QT46-40-1800 2BD
QT50-40-1960 2BD, QT54-40-2120 2BD, QT58-40-2280 2BD


FAQ
1. Does the supplier provide training and documentation on installation and operation?
Yes, we provide installation and operation guidelines, as well as safety regulations. You can also request training services to ensure that your team can correctly install and maintain the new light curtain.
2.Do you provide OEM services for safety light curtain sensors?
Yes, we provide comprehensive OEM services, including customized product selection and laser marking. Our team works closely with clients to understand their unique requirements and provide them with tailored solutions. We can flexibly meet the application needs of different industrial scenarios, from customizing sensor sizes to integrating specific functions.

Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Safety Light Curtain Wiring Diagrams/Dimensional Drawings
safety light curtain Cable description
DADISICK Safety Light Curtain Cable Description
signal output selection (actual output of transistor working normally)
DADISICK Safety Light Curtain Signal Output Selection
NPN output wiring diagram
DADISICK Safety Light Curtain NPN Output Wiring Diagram
PNP output wiring diagram
DADISICK Safety Light Curtain PNP Output Wiring Diagram
safety light curtain Dimension
DADISICK Safety Light Curtain Dimension
Safety-light-curtain QT series-data sheet
Safety-light-curtain QT series user manual
Review
  • Loading...
Please send your message to us
*Email
Tel
*Title
*Content
Upload
  • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.
Industrial Automation Security Solutions