Quick Shipment for Full Safety Sensor Replacement

Home / All / Safety Light Curtain Replacement / XUSL Series Safety Light Curtain Sensor Replacement /

XUSL Series 14 mm Resolution 6 m Sensing Distance 910 mm to 1810 mm Protective Height Type 4 Light Curtain with Finger Protection Replacement

XUSL Series 14 mm Resolution 6 m Sensing Distance 910 mm to 1810 mm Protective Height Type 4 Light Curtain with Finger Protection Replacement

XUSL Series 14 mm Resolution 6 m Sensing Distance 910 mm to 1810 mm Protective Height Type 4 Light Curtain with Finger Protection Replacement
XUSL Series 14 mm Resolution 6 m Sensing Distance 910 mm to 1810 mm Protective Height Type 4 Light Curtain with Finger Protection ReplacementXUSL Series 14 mm Resolution 6 m Sensing Distance 910 mm to 1810 mm Protective Height Type 4 Light Curtain with Finger Protection ReplacementXUSL Series 14 mm Resolution 6 m Sensing Distance 910 mm to 1810 mm Protective Height Type 4 Light Curtain with Finger Protection ReplacementXUSL Series 14 mm Resolution 6 m Sensing Distance 910 mm to 1810 mm Protective Height Type 4 Light Curtain with Finger Protection ReplacementXUSL Series 14 mm Resolution 6 m Sensing Distance 910 mm to 1810 mm Protective Height Type 4 Light Curtain with Finger Protection Replacement
CategoriesXUSL Series Safety Light Curtain Sensor Replacement
BrandDADISICK
ModelXUSL Series | XUSL4E14F091N, XUSL4E14F106N, XUSL4E14F121N, XUSL4E14F136N, XUSL4E14F151N, XUSL4E14F166N, XUSL4E14F181N
Series:XUSL Series
Resolution:14 mm
Scanning range:0 - 3 m, 1 - 6 m
Protective field height:910 mm - 1810 mm
2 Safety outputs (OSSD):2 PNP
Response time:13 - 23.5 ms
Connection type:M12
security level:PLe4
Update TimeSep 19,2024
Detail Information
XUSL Series 14 mm Resolution 6 m Sensing Distance 910 mm to 1810 mm Protective Height Type 4 Light Curtain with Finger Protection Replacement Parameter
Brand
From network
DADISICK
Models
XUSL4E14F091N
QM92-10-910 2BA/2BB
XUSL4E14F106N
QM106-10-1050 2BA/2BB
XUSL4E14F121N
QM122-10-1210 2BA/2BB
XUSL4E14F136N
QM136-10-1350 2BA/2BB
XUSL4E14F151N
QM152-10-1510 2BA/2BB
XUSL4E14F166N
QM166-10-1650 2BA/2BB
XUSL4E14F181N
QM182-10-1810 2BA/2BB
Beam spacing
14 mm
10 mm
Protected altitude
910 mm, 1060 mm, 1210 mm, 1360 mm, 1510 mm, 1660 mm, 1810 mm
910 mm, 1050 mm, 1210 mm, 1350 mm, 1510 mm, 1650 mm, 1810 mm
Scanning range
0 - 3 m, 1 - 6 m
0.3 - 3 m, 0.3 - 6 m
Response time
13 ms - 23.5 ms
≤15 ms
Output method
2 PNP
2 NPN
Reliability and durability
IP65, IP67
IP65
Connector
M12
M12
Housing cross-section
31 mm x 29.4 mm
36 mm x 36 mm
Safety Certificate
CE, cULus, TÜV
TÜV, UL, CE, RoHS, GB
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product model display instructions
The product models displayed on this page are only used to describe and compare the characteristics, specifications, and performance of different products. These models do not represent recommendations or associations for any specific brand or company. When users choose products, please understand and compare the detailed information of each brand's products on your own.
Product recommendations
DADISICK QT Series Machine Light Curtains
Model:
QM92-10-910 2BA/2BB, QM106-10-1050 2BA/2BB
QM122-10-1210 2BA/2BB, QM136-10-1350 2BA/2BB
QM152-10-1510 2BA/2BB, QM166-10-1650 2BA/2BB
QM182-10-1810 2BA/2BB








FAQ
Q: How to maintain and service a safety light curtain?

A:
Good maintenance and care of a safety light curtain are crucial as they directly impact its lifespan and can even affect its safety functions. Therefore, proper maintenance is essential. Here are a few tips based on experience:
Experience 1: Each grating should be regularly inspected and maintained, with dedicated personnel responsible for their care.
Experience 2: Before starting work each day, it is important to check if the safety grating is powered on and functioning properly before operating the machine.
Experience 3: Develop the habit of regularly cleaning the grating, especially the filter plate, to avoid oil stains and dust. If possible, it is recommended to provide a protective cover for the grating.
Experience 4: When replacing or adjusting the mold on the machine, make sure to adjust the height and safety distance of the grating to the appropriate position after completing the task.
Experience 5: Avoid stacking objects near the installation area of the grating to prevent accidental damage.
Experience 6: It is advisable to have a professional inspection or maintenance of the grating performed annually. If any malfunctions occur, do not attempt to repair it yourself, but rather seek the assistance of a professional technician.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Safety Light Curtain Wiring Diagrams/Dimensional Drawings
safety light curtain Cable description
DADISICK Safety Light Curtain Cable Description
signal output selection (actual output of transistor working normally)
DADISICK Safety Light Curtain Signal Output Selection
NPN output wiring diagram
DADISICK Safety Light Curtain NPN Output Wiring Diagram
PNP output wiring diagram
DADISICK Safety Light Curtain PNP Output Wiring Diagram
safety light curtain Dimension
DADISICK Safety Light Curtain Dimension
Safety-light-curtain QM series-data sheet
Safety-light-curtain QM series user manual