Quick Shipment for Full Safety Sensor Replacement

Home / All / Schmersal Replacement / SCHMERSAL Safety Light Curtains Replacement /

For Schmersal SLC440 Series 30 mm Resolution 10 m Sensing Distance 170 mm to 1930 mm Protective Height Safety Light Curtain Replacement

For Schmersal SLC440 Series 30 mm Resolution 10 m Sensing Distance 170 mm to 1930 mm Protective Height Safety Light Curtain Replacement

For Schmersal SLC440 Series 30 mm Resolution 10 m Sensing Distance 170 mm to 1930 mm Protective Height Safety Light Curtain Replacement
For Schmersal SLC440 Series 30 mm Resolution 10 m Sensing Distance 170 mm to 1930 mm Protective Height Safety Light Curtain ReplacementFor Schmersal SLC440 Series 30 mm Resolution 10 m Sensing Distance 170 mm to 1930 mm Protective Height Safety Light Curtain ReplacementFor Schmersal SLC440 Series 30 mm Resolution 10 m Sensing Distance 170 mm to 1930 mm Protective Height Safety Light Curtain ReplacementFor Schmersal SLC440 Series 30 mm Resolution 10 m Sensing Distance 170 mm to 1930 mm Protective Height Safety Light Curtain ReplacementFor Schmersal SLC440 Series 30 mm Resolution 10 m Sensing Distance 170 mm to 1930 mm Protective Height Safety Light Curtain Replacement
CategoriesSCHMERSAL Safety Light Curtains Replacement
BrandDADISICK
ModelSLC440 Series | SLC440-ER-0170-30-01, SLC440-ER-0250-30-01, SLC440-ER-0330-30-01, SLC440-ER-0410-30-01, SLC440-ER-0490-30-01, SLC440-ER-0570-30-01, SLC440-ER-0650-30-01, SLC440-ER-0730-30-01, SLC440-ER-0810-30-01, SLC440-ER-0890-30-01, SLC440-ER-0970-30-01, SLC440-ER-1050-30-01, SLC440-ER-1130-30-01, SLC440-ER-1210-30-01, SLC440-ER-1290-30-01, SLC440-ER-1370-30-01, SLC440-ER-1450-30-01, SLC440-ER-1530-30-01, SLC440-ER-1610-30-01, SLC440-ER-1690-30-01, SLC440-ER-1770-30-01, SLC440-ER-1850-30-01, SLC440-ER-1930-30-01
Series:SLC440 Series
Resolution:30 mm
Scanning range:0.3 - 10 m
Protective field height:170 - 1930 mm
2 Safety outputs (OSSD):2 PNP
Response time:10 - 20 ms
Connection type:M12
security level:PLe4
Update TimeNov 23,2024
Detail Information
For Schmersal SLC440 Series 30 mm Resolution 10 m Sensing Distance 170 mm to 1930 mm Protective Height Safety Light Curtain Replacement Parameter
Brand
From network
DADISICK
Models
SLC440-ER-0170-30-01
QT06-40-200 2BC
SLC440-ER-0250-30-01
QT08-40-280 2BC
SLC440-ER-0330-30-01
QT10-40-360 2BC
SLC440-ER-0410-30-01
QT12-40-440 2BC
SLC440-ER-0490-30-01
QT14-40-520 2BC
SLC440-ER-0570-30-01
QT16-40-600 2BC
SLC440-ER-0650-30-01
QT18-40-680 2BC
SLC440-ER-0730-30-01
QT20-40-760 2BC
SLC440-ER-0810-30-01
QT22-40-840 2BC
SLC440-ER-0890-30-01
QT24-40-920 2BC
SLC440-ER-0970-30-01
QT26-40-1000 2BC
SLC440-ER-1050-30-01
QT28-40-1080 2BC
SLC440-ER-1130-30-01
QT30-40-1160 2BC
SLC440-ER-1210-30-01
QT32-40-1240 2BC
SLC440-ER-1290-30-01
QT34-40-1320 2BC
SLC440-ER-1370-30-01
QT36-40-1400 2BC
SLC440-ER-1450-30-01
QT38-40-1480 2BC
SLC440-ER-1530-30-01
QT40-40-1560 2BC
SLC440-ER-1610-30-01
QT42-40-1640 2BC
SLC440-ER-1690-30-01
QT44-40-1720 2BC
SLC440-ER-1770-30-01
QT46-40-1800 2BC
SLC440-ER-1850-30-01
QT48-40-1880 2BC
SLC440-ER-1930-30-01
QT50-40-1960 2BC
Beam spacing
30 mm
40 mm
Protected altitude
170 mm, 250 mm, 330 mm, 410 mm, 490 mm, 570 mm, 650 mm, 730 mm, 810 mm, 890 mm, 970 mm, 1050 mm, 1130 mm, 1210 mm, 1290 mm, 1370 mm, 1450 mm, 1530 mm, 1610 mm, 1690 mm, 1770 mm, 1850 mm, 1930 mm 
200 mm, 280 mm, 360 mm, 440 mm, 520 mm, 600 mm, 680 mm, 760 mm, 840 mm, 920 mm, 1000 mm, 1080 mm, 1160 mm, 1240 mm, 1320 mm, 1400 mm, 1480 mm, 1560 mm, 1640 mm, 1720 mm, 1800 mm, 1880 mm, 1960 mm
Scanning range
0.3 - 10 m
0.3 - 10 m
Response time
10 ms - 20 ms
≤15 ms
Output method
2 PNP
2 PNP
Reliability and durability
IP67
IP65
Connector
M12
M16
Housing cross-section
33 mm x 27.5 mm
51 mm x 35 mm
Safety Certificate
TÜV, CE, UL
TÜV, UL, CE, RoHS, GB
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand Schmersal's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
DADISICK QT Series Machine Light Curtains
Model:
QT06-40-200 2BC, QT08-40-280 2BC, QT10-40-360 2BC
QT12-40-440 2BC, QT14-40-520 2BC, QT16-40-600 2BC
QT18-40-680 2BC, QT20-40-760 2BC, QT22-40-840 2BC
QT24-40-920 2BC, QT26-40-1000 2BC, QT28-40-1080 2BC
QT30-40-1160 2BC, QT32-40-1240 2BC, QT34-40-1320 2BC
QT36-40-1400 2BC, QT38-40-1480 2BC, QT40-40-1560 2BC
QT42-40-1640 2BC, QT44-40-1720 2BC, QT46-40-1800 2BC
QT48-40-1880 2BC, QT50-40-1960 2BC




FAQ
Q: How is a safety light curtain used in an injection molding machine?

A:
A safety light curtain is an advanced optoelectronic protective device that can be used as a safety guard, infrared safety guard, or press protection device. It is suitable for potential hazardous machinery such as stamping machines, forging machines, and automated equipment, which can pose a risk of personal injury. The installation of a safety light curtain can effectively protect personal safety.

Injection molding machines and punch presses are both large-scale mechanical equipment. When installing safety light curtain protection devices, special methods can be used for protection. Based on the actual usage of injection molding machines, the selection and improvement of self-checking functions of safety light curtains can be done to determine the beam spacing, height protection, distance protection, and output mode, ensuring that when a safety light curtain malfunctions, it does not send incorrect signals to the controlled equipment.

Maintenance, repair, and upkeep of injection molding machines must be carried out by qualified and experienced experts or technicians. The operation of the injection molding machine should only be done when all safety devices are functioning properly. The safety light curtain protection device installed on the machine is designed to protect the operator's personal safety and ensure that the product and equipment are not damaged. Therefore, it is not allowed to dismantle safety light curtains or other protective devices without proper authorization, and the software programs in the devices should not be modified randomly. Before using the machine, it is necessary to check whether the safety protection devices are functioning correctly.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Safety Light Curtain Wiring Diagrams/Dimensional Drawings
safety light curtain Cable description
DADISICK Safety Light Curtain Cable Description
signal output selection (actual output of transistor working normally)
DADISICK Safety Light Curtain Signal Output Selection
NPN output wiring diagram
DADISICK Safety Light Curtain NPN Output Wiring Diagram
PNP output wiring diagram
DADISICK Safety Light Curtain PNP Output Wiring Diagram
safety light curtain Dimension
DADISICK Safety Light Curtain Dimension
Review
  • Loading...
Please send your message to us
*Email
Tel
*Title
*Content
Upload
  • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.
Industrial Automation Security Solutions