Quick Shipment for Full Safety Sensor Replacement

Home / All / Schmersal Replacement / SCHMERSAL Safety Light Curtains Replacement /

For Schmersal SLC440 Series 14 mm Resolution 10 m Sensing Distance 730 mm to 1930 mm Protective Height Extended Light Curtain Replacement

For Schmersal SLC440 Series 14 mm Resolution 10 m Sensing Distance 730 mm to 1930 mm Protective Height Extended Light Curtain Replacement

For Schmersal SLC440 Series 14 mm Resolution 10 m Sensing Distance 730 mm to 1930 mm Protective Height Extended Light Curtain Replacement
For Schmersal SLC440 Series 14 mm Resolution 10 m Sensing Distance 730 mm to 1930 mm Protective Height Extended Light Curtain ReplacementFor Schmersal SLC440 Series 14 mm Resolution 10 m Sensing Distance 730 mm to 1930 mm Protective Height Extended Light Curtain ReplacementFor Schmersal SLC440 Series 14 mm Resolution 10 m Sensing Distance 730 mm to 1930 mm Protective Height Extended Light Curtain ReplacementFor Schmersal SLC440 Series 14 mm Resolution 10 m Sensing Distance 730 mm to 1930 mm Protective Height Extended Light Curtain ReplacementFor Schmersal SLC440 Series 14 mm Resolution 10 m Sensing Distance 730 mm to 1930 mm Protective Height Extended Light Curtain Replacement
CategoriesSCHMERSAL Safety Light Curtains Replacement
BrandDADISICK
ModelSLC440 Series | SLC440-ER-0730-14-H1, SLC440-ER-0810-14-H1, SLC440-ER-0890-14-H1, SLC440-ER-0970-14-H1, SLC440-ER-1050-14-H1, SLC440-ER-1130-14-H1, SLC440-ER-1210-14-H1, SLC440-ER-1290-14-H1, SLC440-ER-1370-14-H1, SLC440-ER-1450-14-H1, SLC440-ER-1530-14-H1, SLC440-ER-1610-14-H1, SLC440-ER-1690-14-H1, SLC440-ER-1770-14-H1, SLC440-ER-1850-14-H1, SLC440-ER-1930-14-H1
Series:SLC440 Series
Resolution:14 mm
Scanning range:3 - 10 m
Protective field height:730 - 1930 mm
2 Safety outputs (OSSD):2 PNP
Response time:20 - 28 ms
Connection type:M12
security level:PLe4
Update TimeNov 21,2024
Detail Information
For Schmersal SLC440 Series 14 mm Resolution 10 m Sensing Distance 730 mm to 1930 mm Protective Height Extended Light Curtain Replacement Parameter
Brand
From network
DADISICK
Models
SLC440-ER-0730-14-H1
QMT74-10-730 2BC
SLC440-ER-0810-14-H1
QMT82-10-810 2BC
SLC440-ER-0890-14-H1
QMT90-10-890 2BC
SLC440-ER-0970-14-H1
QMT98-10-970 2BC
SLC440-ER-1050-14-H1
QMT106-10-1050 2BC
SLC440-ER-1130-14-H1
QMT114-10-1130 2BC
SLC440-ER-1210-14-H1
QMT122-10-1210 2BC
SLC440-ER-1290-14-H1
QMT130-10-1290 2BC
SLC440-ER-1370-14-H1
QMT138-10-1370 2BC
SLC440-ER-1450-14-H1
QMT146-10-1450 2BC
SLC440-ER-1530-14-H1
QMT154-10-1530 2BC
SLC440-ER-1610-14-H1
QMT162-10-1610 2BC
SLC440-ER-1690-14-H1
QMT170-10-1690 2BC
SLC440-ER-1770-14-H1
QMT178-10-1770 2BC
SLC440-ER-1850-14-H1
QMT186-10-1850 2BC
SLC440-ER-1930-14-H1
QMT194-10-1930 2BC
Beam spacing
14 mm
10 mm
Protected altitude
730 mm, 810 mm, 890 mm, 970 mm, 1050 mm, 1130 mm, 1210 mm, 1290 mm, 1370 mm, 1450 mm, 1530 mm, 1610 mm, 1690 mm, 1770 mm, 1850 mm, 1930 mm
730 mm, 810 mm, 890 mm, 970 mm, 1050 mm, 1130 mm, 1210 mm, 1290 mm, 1370 mm, 1450 mm, 1530 mm, 1610 mm, 1690 mm, 1770 mm, 1850 mm, 1930 mm
Scanning range
3 - 10 m
0.3 - 10 m
Response time
20 ms - 28 ms
≤15 ms
Output method
2 PNP
2 PNP
Reliability and durability
IP67
IP65
Connector
M12
M16
Housing cross-section
33 mm x 27.8 mm
51 mm x 35 mm
Safety Certificate
CE, UL
TÜV, UL, CE, RoHS, GB
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand Schmersal's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
DADISICK QMT Series Machine Light Curtains
Model:
QMT74-10-730 2BC, QMT82-10-810 2BC, QMT90-10-890 2BC
QMT98-10-970 2BC, QMT106-10-1050 2BC, QMT114-10-1130 2BC
QMT122-10-1210 2BC, QMT130-10-1290 2BC, QMT138-10-1370 2BC
QMT146-10-1450 2BC, QMT154-10-1530 2BC, QMT162-10-1610 2BC
QMT170-10-1690 2BC, QMT178-10-1770 2BC, QMT186-10-1850 2BC
QMT194-10-1930 2BC




FAQ
Q: What to do when a safety light curtain malfunctions?
A:
Safety light curtains are important safety devices used to protect workers and equipment. However, even high-quality safety light curtains may experience malfunctions. This article will discuss common safety light curtain malfunctions and provide troubleshooting solutions to help you resolve the issues promptly.

1. Safety light curtain not functioning properly

If the safety light curtain is not functioning properly, first check if the power supply is working correctly. Ensure that the power cable is connected properly and check if the indicator lights on the light curtain are illuminated. If the indicator lights are on, it may indicate a power supply issue that requires either replacing the power supply or repairing the power cable.

Additionally, check the connection between the emitter and receiver of the light curtain to ensure it is secure. Sometimes, the connection may become loose or disconnected, resulting in the failure to transmit light signals. Reconnect the emitter and receiver, ensuring a secure connection.

2. False alarms from safety light curtain

If the safety light curtain is frequently producing false alarms, meaning it signals an alert even when no objects or personnel are entering, it may be experiencing interference. First, check the surrounding environment for any reflective objects or bright light sources. These objects or light sources can interfere with the proper operation of the light curtain.

Additionally, check if there are any obstacles blocking the transmission of light between the emitter and receiver of the light curtain. If there are objects or dust obstructing the transmission of light, remove them or reinstall the light curtain to ensure smooth light transmission.

3. Sensitivity issues with safety light curtain

If the sensitivity of the safety light curtain is either too high or too low, meaning it fails to produce an alert signal when obstacles are present, it may require adjusting the sensitivity settings. Refer to the user manual of the light curtain to learn how to adjust its sensitivity.

While adjusting the sensitivity, you can try gradually increasing or decreasing the sensitivity settings until you achieve the desired alert effect. If the issue persists, it may be necessary to check if the receiver of the safety light curtain is damaged or needs replacement.

For more complex malfunctions, it is recommended to seek assistance from professional technical support personnel for inspection and repair. They have extensive experience and expertise that can help you quickly resolve the issues with your safety light curtain.

In summary, when a safety light curtain malfunctions, first check if the power supply is working properly, and ensure that the connection between the light emitter and receiver is secure. If there are false alarms or sensitivity issues, settings can be adjusted or obstructions can be cleared. For complex malfunctions, it is recommended to seek professional technical support. Ensuring the proper functioning of the safety light curtain is crucial for protecting the safety of workers and equipment. 
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Safety Light Curtain Wiring Diagrams/Dimensional Drawings
safety light curtain Cable description
DADISICK Safety Light Curtain Cable Description
signal output selection (actual output of transistor working normally)
DADISICK Safety Light Curtain Signal Output Selection
NPN output wiring diagram
DADISICK Safety Light Curtain NPN Output Wiring Diagram
PNP output wiring diagram
DADISICK Safety Light Curtain PNP Output Wiring Diagram
safety light curtain Dimension
DADISICK Safety Light Curtain Dimension
Review
  • Loading...
Please send your message to us
*Email
Tel
*Title
*Content
Upload
  • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.
Industrial Automation Security Solutions