Quick Shipment for Full Safety Sensor Replacement

Home / All / Safety Light Grid Replacement / SGS Series Type 4 Safety Light Grids Replacement /

SGSMP / SGS Series Type 4 Safety Light Grids Replacement 300/400/500 mm Resolution | 30 m Operating Range | 500 mm to 1200 mm Protective Height

SGSMP / SGS Series Type 4 Safety Light Grids Replacement 300/400/500 mm Resolution | 30 m Operating Range | 500 mm to 1200 mm Protective Height

SGSMP / SGS Series Type 4 Safety Light Grids Replacement 300/400/500 mm Resolution | 30 m Operating Range | 500 mm to 1200 mm Protective Height
SGSMP / SGS Series Type 4 Safety Light Grids Replacement 300/400/500 mm Resolution | 30 m Operating Range | 500 mm to 1200 mm Protective HeightSGSMP / SGS Series Type 4 Safety Light Grids Replacement 300/400/500 mm Resolution | 30 m Operating Range | 500 mm to 1200 mm Protective HeightSGSMP / SGS Series Type 4 Safety Light Grids Replacement 300/400/500 mm Resolution | 30 m Operating Range | 500 mm to 1200 mm Protective HeightSGSMP / SGS Series Type 4 Safety Light Grids Replacement 300/400/500 mm Resolution | 30 m Operating Range | 500 mm to 1200 mm Protective HeightSGSMP / SGS Series Type 4 Safety Light Grids Replacement 300/400/500 mm Resolution | 30 m Operating Range | 500 mm to 1200 mm Protective Height
CategoriesSGS Series Type 4 Safety Light Grids Replacement
BrandDADISICK
ModelSGS Series | SGSMP4-300Q128, SGSMP3-400Q128, SGSMP4-400Q128, SGSMP2-500Q128
Series:SGS Series
Resolution:300 mm / 400 mm / 500 mm
Scanning range:0.5 m - 30 m
Protective field height:500 mm - 1200 mm
2 Safety outputs (OSSD):2 PNP
Response time:12 ms - 14 ms
Connection type:M12
Security level:PLe4
Update TimeSep 17,2024
Detail Information
SGS Series Type 4 Safety Light Grids Replacement Parameter
Brand
From network
DADISICK
Models
SGSMP4-300Q128
QT06-200-1000-2BG
SGSMP3-400Q128
QT04-200-600-2BG
SGSMP4-400Q128
QT08-200-1400-2BG
SGSMP2-500Q128
QT04-200-600-2BG
Beam spacing
300 mm/ 400 mm / 400 mm / 500 mm
200 mm
Protected altitude
900 mm, 800 mm, 1200 mm, 500 mm
1000 mm, 600 mm, 1400 mm, 600 mm
Scanning range
0.5 m - 30 m
0.3 m - 30 m
Response time
12 ms - 14 ms
≤15 ms
Output method
2 PNP
2 PNP
Reliability and durability
IP65
IP65
Connector
M12
M16
Housing cross-section
56.9 mm × 52 mm
35 mm × 51 mm
Safety Certificate
cULus, CE
TÜV, UL, CE, RoHS, GB
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product model display instructions
The product models displayed on this page are only used to describe and compare the characteristics, specifications, and performance of different products. These models do not represent recommendations or associations for any specific brand or company. When users choose products, please understand and compare the detailed information of each brand's products on your own.
Product recommendations
DADISICK Safety Light Curtains
Model:
QT06-200-1000-2BG, QT04-200-600-2BG, QT08-200-1400-2BG, QT04-200-600-2BG

FAQ
How does the performance of safety light curtains hold up under conditions such as dust, moisture, and other environmental factors?
The protection level (IP code) of safety light curtains is an important indicator, representing the product's ability to resist dust and water. For applications with harsh environmental conditions, safety light curtains with higher protection levels can be selected to ensure they can withstand dust and moisture to a certain extent. Generally, the higher the protection level, the better the performance of the light curtains in harsh environments.

However, even with a higher protection level, safety light curtains may still be affected by factors such as dust and moisture. For example, excessive dust or dirt covering the light curtains may block some beams, leading to a decrease in detection accuracy. Additionally, moisture may cause the internal electronic components of the light curtains to become damp, thereby affecting their performance.

To address these challenges, some measures can be taken to improve the performance of safety light curtains in harsh environments. For instance, regularly clean the surface of the light curtains to ensure they are in good working condition; in humid environments, choose light curtains with moisture-resistant features or implement other moisture-proof measures; in environments with a lot of dust, select light curtains with dust-proof features or add dust covers and other protective measures.

Furthermore, the design and selection of safety light curtains are also crucial. When selecting, choose light curtains with appropriate parameters such as resolution, detection distance, and response time based on the actual application requirements. Additionally, consider factors such as the communication interface, ease of installation and maintenance to ensure they can be effectively integrated with other equipment and reduce the operating costs of the system.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Safety Light Curtain Wiring Diagrams/Dimensional Drawings
safety light curtain Cable description
DADISICK Safety Light Curtain Cable Description
signal output selection (actual output of transistor working normally)
DADISICK Light Curtain Signal Output Selection
NPN output wiring diagram
DADISICK Light Curtain NPN Output Wiring Diagram
PNP output wiring diagram
DADISICK Light Curtain PNP Output Wiring Diagram
safety light curtain Dimension
DADISICK Safety Light Curtain Dimension
Safety-light-curtain QT Series Data Sheet
Safety-light-curtain QT Series User Manual
Review
  • Loading...
Please send your message to us
*Email
Tel
*Title
*Content
Upload
  • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.
Industrial Automation Security Solutions