Quick Shipment for Full Safety Sensor Replacement

Home / All / Safety Light Curtain Replacement / MLC 510 / 520 series Safety Light Curtain Replacement /

MLC 510 / 520 Series Light Curtain Sensor Replacement 40 mm Resolution 300 mm to 1800 mm Protection Height

MLC 510 / 520 Series Light Curtain Sensor Replacement 40 mm Resolution 300 mm to 1800 mm Protection Height

MLC 510 / 520 Series  Light Curtain Sensor Replacement 40 mm Resolution 300 mm to 1800 mm Protection Height
MLC 510 / 520 Series  Light Curtain Sensor Replacement 40 mm Resolution 300 mm to 1800 mm Protection HeightMLC 510 / 520 Series  Light Curtain Sensor Replacement 40 mm Resolution 300 mm to 1800 mm Protection HeightMLC 510 / 520 Series  Light Curtain Sensor Replacement 40 mm Resolution 300 mm to 1800 mm Protection HeightMLC 510 / 520 Series  Light Curtain Sensor Replacement 40 mm Resolution 300 mm to 1800 mm Protection HeightMLC 510 / 520 Series  Light Curtain Sensor Replacement 40 mm Resolution 300 mm to 1800 mm Protection Height
CategoriesMLC 510 / 520 series Safety Light Curtain Replacement
BrandDADISICK
ModelMLC 510 / 520 Series | MLC500T40-300MG, MLC520R40-300MG, MLC500T40-450MG, MLC520R40-450MG, MLC500T40-600MG, MLC520R40-600MG, MLC500T40-750MG, MLC520R40-750MG, MLC500T40-900MG, MLC520R40-900MG, MLC500T40-1050MG, MLC520R40-1050MG, MLC500T40-1200MG, MLC520R40-1200MG, MLC500T40-1350MG, MLC520R40-1350MG, MLC500T40-1500MG, MLC520R40-1500MG, MLC500T40-1650MG, MLC520R40-1650MG, MLC500T40-1800MG, MLC520R40-1800MG
Series:MLC 510 / 520 Series
Resolution:40 mm
Scanning range:0 - 20 m
Protective field height:300 - 1800 mm
2 Safety outputs (OSSD):2 PNP
Response time:4 - 17 ms
Connection type:M12
Security level:PLe4
Update TimeSep 19,2024
Detail Information
MLC 510 / 520 Series  Light Curtain Sensor Replacement 40 mm Resolution 300 mm to 1800 mm Protection Height Parameter
Brand
Transmitter
Receiver
DADISICK
Models
MCL500T40-300MG
MLC520R40-300MG
QT08-40-280 2BE
MLC500T40-450MG
MLC520R40-450MG
QT12-40-440 2BE
MLC500T40-600MG
MLC520R40-600MG
QT16-40-600 2BE
MLC500T40-750MG
MLC520R40-750MG
QT20-40-760 2BE
MLC500T40-900MG
MLC520R40-900MG
QT24-40-920 2BE
MLC500T40-1050MG
MLC520R40-1050MG
QT28-40-1080 2BE
MLC500T40-1200MG
MLC520R40-1200MG
QT30-40-1160 2BE
MLC500T40-1350MG
MLC520R40-1350MG
QT34-40-1320 2BE
MLC500T40-1500MG
MLC520R40-1500MG
QT38-40-1480 2BE
MLC500T40-1650MG
MLC520R40-1650MG
QT42-40-1640 2BE
MLC500T40-1800MG
MLC520R40-1800MG
QT46-40-1800 2BE
Beam spacing
40  mm
40 mm
Protected altitude
300 mm, 450 mm, 600 mm, 750 mm, 900 mm, 1050 mm, 1200 mm, 1350 mm, 1500 mm, 1650 mm, 1800 mm
280 mm, 440 mm, 600 mm, 760 mm, 920 mm, 1080 mm, 1160 mm, 1320 mm, 1480 mm, 1640 mm, 1800 mm
Scanning range
0 - 20 m
0.3 - 20 m
Response time
4 - 17 ms
≤15 ms
Output method
2 PNP
2 PNP
Reliability and durability
IP65
IP65
Connector
M12
M16
Housing cross-section
53 mm x 29 mm
51 mm x 35 mm
Safety Certificate
KCs, TÜV Süd, c TÜV NRTL US, c UL US, PLe4
TUV, UL, CE, RoSH, GB
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product model display instructions
The product models displayed on this page are only used to describe and compare the characteristics, specifications, and performance of different products. These models do not represent recommendations or associations for any specific brand or company. When users choose products, please understand and compare the detailed information of each brand's products on your own.
Product recommendations
DADISICK Light Curtain Safety Device
Model:
QT08-40-280 2BE, QT12-40-440 2BE, QT16-40-600 2BE
QT20-40-760 2BE, QT24-40-920 2BE, QT28-40-1080 2BE
QT30-40-1160 2BE, QT34-40-1320 2BE, QT38-40-1480 2BE
QT42-40-1640 2BE, QT46-40-1800 2BE



FAQ
1. What standards do your safety light curtains meet?
Our light curtain products have undergone strict testing and comply with relevant safety standards in multiple countries and regions, such as Chinese GB/T 19001-2016, ISO 9001:2015, International Electrotechnical Society IEC61496-1/2 standard safety level, EU CE certification, and South Germany TUV certification.
2.What tests should I perform after installing a new light screen?
We suggest conducting functional testing and security verification to ensure that the new light curtain can function properly. The testing items include detection range, response time, and alarm function.
3.Is the new light curtain compatible with the existing system?
We provide 1:1 customized replacement of the original light curtain data connector, with compatibility including electrical interfaces, communication protocols, and mechanical installation. Please compare the specifications of existing light curtains with ours, or contact our technical support team to help you find a compatible replacement model.

Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Safety Light Curtain Wiring Diagrams/Dimensional Drawings
safety light curtain Cable description
Machine Light Curtains Cable Description
signal output selection (actual output of transistor working normally)
Machine Safety Devices Signal Output Selection
NPN output wiring diagram
Press Brake Safety Light Curtains NPN Output Wiring Diagram
PNP output wiring diagram
Punch Press Guarding PNP Output Wiring Diagram
safety light curtain Dimension
DADISICK Punch Press Safety Guards Dimension
Safety-light-curtain QT series-data sheet
Safety-light-curtain QT series user manual
Review
  • Loading...
Please send your message to us
*Email
Tel
*Title
*Content
Upload
  • Only supports .rar/.zip/.jpg/.png/.gif/.doc/.xls/.pdf, maximum 20MB.
Industrial Automation Security Solutions