Quick Shipment for Full Safety Sensor Replacement

Home / All / OMRON Replacement / OMRON Safety Light Curtains Replacement /

For OMRON F3SJ-B Series Safety Light Curtain Replacement 20 mm Resolution | 7 m Operating Range | 185 mm to 1425 mm Protective Height

For OMRON F3SJ-B Series Safety Light Curtain Replacement 20 mm Resolution | 7 m Operating Range | 185 mm to 1425 mm Protective Height

For OMRON F3SJ-B Series Safety Light Curtain Replacement 20 mm Resolution | 7 m Operating Range | 185 mm to 1425 mm Protective Height
For OMRON F3SJ-B Series Safety Light Curtain Replacement 20 mm Resolution | 7 m Operating Range | 185 mm to 1425 mm Protective HeightFor OMRON F3SJ-B Series Safety Light Curtain Replacement 20 mm Resolution | 7 m Operating Range | 185 mm to 1425 mm Protective HeightFor OMRON F3SJ-B Series Safety Light Curtain Replacement 20 mm Resolution | 7 m Operating Range | 185 mm to 1425 mm Protective HeightFor OMRON F3SJ-B Series Safety Light Curtain Replacement 20 mm Resolution | 7 m Operating Range | 185 mm to 1425 mm Protective HeightFor OMRON F3SJ-B Series Safety Light Curtain Replacement 20 mm Resolution | 7 m Operating Range | 185 mm to 1425 mm Protective Height
CategoriesOMRON Safety Light Curtains Replacement
BrandDADISICK
ModelF3SJ-B Series | F3SJ-B0185P25-01TS, F3SJ-B0225P25-01TS, F3SJ-B0305P25-01TS, F3SJ-B0385P25-01TS, F3SJ-B0465P25-01TS, F3SJ-B0545P25-01TS, F3SJ-B0625P25-01TS, F3SJ-B0705P25-01TS, F3SJ-B0785P25-01TS, F3SJ-B0865P25-01TS, F3SJ-B0945P25-01TS, F3SJ-B1025P25-01TS, F3SJ-B1105P25-01TS, F3SJ-B1185P25-01TS, F3SJ-B1265P25-01TS, F3SJ-B1345P25-01TS, F3SJ-B1425P25-01TS
Series:F3SJ-B Series
Resolution:20 mm
Scanning range:0.2 m - 7 m
Protective field height:185 mm - 1425 mm
2 Safety outputs (OSSD):2 PNP
Response time:15 ms
Connection type:M12
Security level:PLe4
Update TimeNov 21,2024
Detail Information
For OMRON F3SJ-B Series Safety Light Curtain Replacement Parameter
Brand
From network
DADISICK
Models
F3SJ-B0185P25-01TS
QT10-20-180-2BC
F3SJ-B0225P25-01TS
QT12-20-220-2BC
F3SJ-B0305P25-01TS
QT16-20-300-2BC
F3SJ-B0385P25-01TS
QT20-20-380-2BC
F3SJ-B0465P25-01TS
QT24-20-460-2BC
F3SJ-B0545P25-01TS
QT28-20-540-2BC
F3SJ-B0625P25-01TS
QT32-20-620-2BC
F3SJ-B0705P25-01TS
QT36-20-700-2BC
F3SJ-B0785P25-01TS
QT40-20-780-2BC
F3SJ-B0865P25-01TS
QT44-20-860-2BC
F3SJ-B0945P25-01TS
QT48-20-940-2BC
F3SJ-B1025P25-01TS
QT52-20-1020-2BC
F3SJ-B1105P25-01TS
QT56-20-1100-2BC
F3SJ-B1185P25-01TS
QT60-20-1180-2BC
F3SJ-B1265P25-01TS
QT64-20-1260-2BC
F3SJ-B1345P25-01TS
QT68-20-1340-2BC
F3SJ-B1425P25-01TS
QT72-20-1420-2BC
Beam spacing
20 mm
20 mm
Protected altitude
185 mm, 225 mm, 305 mm, 385 mm, 
465 mm, 545 mm, 625 mm, 705 mm, 
785 mm, 865 mm, 945 mm, 1025 mm, 
1105 mm, 1185 mm, 1265 mm, 1345 mm, 
1425 mm
180 mm, 220 mm, 300 mm, 380 mm, 
460 mm, 540 mm, 620 mm, 700 mm, 
780 mm, 860 mm, 940 mm, 1020 mm, 
1100 mm, 1180 mm, 1260 mm, 1340 mm, 
1420 mm
Scanning range
0.2 m - 7 m
0.3 m - 10 m
Response time
15 ms
≤15 ms
Output method
2 PNP
2 PNP
Reliability and durability
IP65
IP65
Connector
M12
M16
Housing cross-section
45 mm × 30 mm
35 mm × 51 mm
Safety Certificate
CE, TÜV, UL, S-Mark
TÜV, UL, CE, RoHS, GB
We are able to reproduce the specific connection configuration of each brand with high level of accuracy.
Product model display instructions
The brands and specifications shown on this page are for product selection only. Our safety light curtain is a safety part made by DADISICK, not official brand OMRON's products. DAIDSICK offer replacement for official brand products. We are not the owner of the brands. If you need to buy official brand products, please contact the brand official representative.
Product recommendations
DADISICK Safety Light Curtains
Model:
QT10-20-180-2BC, QT12-20-220-2BC, QT16-20-300-2BC, QT20-20-380-2BC, QT24-20-460-2BC, QT28-20-540-2BC, QT32-20-620-2BC, QT36-20-700-2BC, QT40-20-780-2BC, QT44-20-860-2BC, QT48-20-940-2BC, QT52-20-1020-2BC, QT56-20-1100-2BC, QT60-20-1180-2BC, QT64-20-1260-2BC, QT68-20-1340-2BC, QT72-20-1420-2BC

FAQ
Do suppliers offer installation and operation training and documentation?
Yes, we provide installation and operation guides, as well as safety protocols. You can also request training services to ensure your team can properly install and maintain the new light curtain.
Disclaimers
The product model information provided on this website is sourced from public channels, aiming to provide users with reference for product comparison and selection. This website does not guarantee the accuracy, completeness, or reliability of information, nor does it constitute a recommendation or recognition of any brand or company. Users should verify and bear corresponding risks when using the information provided on this website. This website shall not be liable for any loss or damage caused by the use of information on this website.
Safety Light Curtain Wiring Diagrams/Dimensional Drawings
safety light curtain Cable description
DADISICK Safety Light Curtain Cable Description
signal output selection (actual output of transistor working normally)
DADISICK Light Curtain Signal Output Selection
NPN output wiring diagram
DADISICK Light Curtain NPN Output Wiring Diagram
PNP output wiring diagram
DADISICK Light Curtain PNP Output Wiring Diagram
safety light curtain Dimension
DADISICK Safety Light Curtain Dimension
Safety-light-curtain QT Series Data Sheet
Safety-light-curtain QT Series User Manual